{"title":"Gas Mask Filters","description":null,"products":[{"product_id":"mira-safety-vk-530-smoke-carbon-monoxide-filter-cartridges","title":"MIRA Safety VK-530 Smoke \/ Carbon Monoxide Filter Cartridges","description":"\u003cp\u003e \u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eTransform your gas mask into a reliable, fully functioning multiuse smoke hood with these VK-530 filters. Designed to overcome smoke and particulates (along with high concentrations of carbon monoxide), these advanced filters provide crucial hours of protection and clean air from some of the most common disasters faced by US citizens. Grab a few VK-530 filters for your family today!\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #8b6a1b;\" data-mce-style=\"color: #8b6a1b;\"\u003eKEY FEATURES OF MIRA Safety VK-530\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cdiv id=\"subsection-content-2\" class=\"technical-data subsection-content\"\u003e\n\u003cul\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eProven design provides comprehensive protection from a wide range of toxic industrial chemicals, smoke, and particulates.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eRated at A2B2E2K2HgNO20COP3R. \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eSmoke respirator mask filters can be used in environments with as little as 19.5% oxygen.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eOffers protection against organic gasses and vapors with a boiling point \u0026gt;65°C.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eProvides protection from inorganic gasses and vapors, sulfur dioxide, ammonia, oxides of nitrogen, carbon monoxide, mercury vapors, and compounds, as well as particles of toxic and highly toxic substances (P3).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eEach filter is sealed and clearly labeled with its expiration date.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eFive-year shelf life.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eManufacturer’s warranty ensures filters perform to specifications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eManufactured in Italy. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-data subsection-content\" id=\"subsection-content-2\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\" data-mce-style=\"color: #8b6a1b;\"\u003eTurn Your Gas Mask into a Respirator for Smoke with the VK-530\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv id=\"subsection-content-4\" class=\"technical-data subsection-content\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eWildfires are a constant threat to the Western United States—where thousands of citizens may be forced to evacuate at a moment’s notice through choking clouds of smoke and searing heat. Meanwhile, over 71,000 homes are lost in structure fires \u003c\/span\u003e\u003ci data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eevery year, \u003c\/span\u003e\u003c\/i\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eaccording to studies from the National Fire Protection Association (NFPA). Nevertheless, few own escape respirators or fire protection hoods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eThat means that fire poses an immediate threat to millions of unprepared American families. Thankfully, VK-530 gas mask filters provide a solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eWhile most conventional multi-gas filters can protect you from a wide array of toxic industrial chemicals, the VK-530 is one of just a few filters that can protect you from carbon monoxide and minimize the risk of smoke inhalation. More specifically, the VK-530 helps to convert CO into CO2, allowing you to breathe it out. This means that gone are the days of you keeping an extra single-use fire\/smoke hood on hand! Instead, you can use your existing gas mask for smoke protection in case of a house fire or wildfire.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eIf you’ve got a gas mask, or if you’re thinking about getting one, don’t overlook these flexible filters. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eStorage\u003c\/b\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eVK-530 filters should be stored at 2°C (35.6°F) to 55°C (131°F), with humidity lower than 80%, away from any significant sources of vibration. They should be protected from solar radiation, oxidant agents, shocks, and anything that could make the filters fall down. Do not allow filters to come into contact with ketones, esters, hydrocarbons, acids and strong bases, high pressure fluids, and liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-data subsection-content\" id=\"subsection-content-6\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cstrong\u003eNote that the predecessor (VK-450) has been out of stock for the past year, so we expect the VK-530 to sell out quickly. Act now to get yours in time for the wildfire season.\u003c\/strong\u003e","brand":"MIRA Safety","offers":[{"title":"Default Title","offer_id":44516538155184,"sku":"MIRA-VK530","price":224.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/7725\/4832\/files\/mira-safety-vk-530-smoke-carbon-monoxide-filter-cartridges-tactical-source-llc.jpg?v=1750239014"},{"product_id":"mira-safety-p-can-police-and-corrections-gas-mask-filter","title":"Mira Safety P-CAN Police and Corrections Gas Mask Filter","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eThe Mira Safety P-CAN Police and Corrections Gas Mask Filter is one of the world’s most advanced solutions for potential long-term exposure to riot control gasses including CS, CN, and OC. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eFeaturing the same basic characteristics as other MIRA Safety filters, these hydrophobic P3 police gas mask filters have almost 3 times as much activated carbon as competing filters, providing up to 12 hours of rock-solid, reliable protection, even in wet conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eThe filters are produced with standard round threads according to STANAG 4155 (EN 148-1)- Rd 40 x 1\/7\". In addition to a shelf life of almost double than competing filters, they also meet EN 14387:2004 + A1:2008 standards for the removal of CS\/CN gas in vapor form. Individual canisters are vacuum-sealed, dated, and black in color for easy identification in inventory.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003e Features of Mira Safety P-CAN Police and Corrections Gas Mask Filter \u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eSpecifically designed for law enforcement professionals for use with riot control agents\/tear gases including CS, CN, and OC pepper spray\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eHydrophobic coating on the embedded P3 filter ensures reliable function in rain, snow, or practically any conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\n\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eLonger-lasting protection with almost 3X the activated carbon of competitors (250 cm\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e3\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003evs. 90 cm\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e3\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eDelivers over 12 hours of reliable protection from riot control agents—giving officers the confidence they need to keep the peace\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eCompatible with standard 40 mm NATO-threaded respirators, which are widely available\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e10-year shelf life—long-term savings and practical logistics with police gas mask filters that will remain usable for half an officer’s career\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eWeighs in at just 290 grams (10.2 oz) with a diameter of just 111 mm (4.3 inches)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eBased on MIRA Safety filter design used by military personnel, CBRN specialists, and special operations forces all over the world\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eCertified by European agencies and bearing the “CE” symbol, compliant under EN 14387:2004 + A1:2008\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eWhen Regular Filters Just Won’t Cut it\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003ePolice in many American cities have come to realize that the filters that came with their standard riot gear start to saturate and fail fairly quickly. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eThat’s where our new P-CAN police gas mask filter comes in. Designed specifically with the needs of riot police in mind, it can withstand prolonged exposure to all major riot control agents—in practically all climates—with a shelf life that spans half an officer’s career.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eExposure to riot control agents and their lachrymatory effects is enough to take an officer out of action for up to an hour. The results can only make a bad situation worse.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eProtect yourself with the most cutting-edge new police gas mask filter on the market today—MIRA Safety’s P-CAN filter. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-2fdn{border-color:#9b9b9b;text-align:left;vertical-align:top}\n.tg .tg-4ypd{background-color:#efefef;border-color:#9b9b9b;text-align:left;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-4ypd\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eTechnical Data\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-4ypd\" colspan=\"4\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBreathing Resistance in Pa\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDiameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e110 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e@ flow rate 30 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e@ flow rate 95 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eHeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e75 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eEN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eP-CAN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eEN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eP-CAN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e290 g ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e260\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u0026lt;160\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e980\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u0026lt;600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eStorage time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e10 years (factory sealed)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4ypd\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eType and Class Particle filter efficiency @ flow rate 95l\/m \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-4ypd\" colspan=\"4\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eParticle filter efficiency @ flow rate 95l\/m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eA2 - organic gases and vapours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eP3 - particles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\" rowspan=\"3\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eSodium Chloride NaCl (S)\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 400;\"\u003eParaffin oil (L)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\" rowspan=\"3\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eEN\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 400;\"\u003e99.95\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 400;\"\u003e99.95\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\" colspan=\"2\" rowspan=\"3\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eNBC-77 SOF\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u0026gt;99.999\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u0026gt;99.999\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eSX - LE Agents\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eD- dust\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2fdn\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eR- reusable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e1) requirement of European Standard EN 14387+A1\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e2) the filter was tested on dolomite dust clogging\u003c\/span\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eENVIRONMENTAL CONSIDERATIONS:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eThanks to its hydrophobic P3 filter that’s embedded, these police gas mask filters can be exposed to sustained heavy rainfall without water ingress. They’ve been tested to perform at temperatures as low as -32° Celsius and exposed to temperatures of up to 159° Fahrenheit. They’re also functional in a full range of humidity—from 5% all the way up to 100%. Salt breeze will not deteriorate the filter, but prolonged exposure will limit it to a service life of 12–24 hours maximum.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eSTORAGE AND MAINTENANCE:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eThe filters are sealed in plastic bags by the manufacturer. Store the filters unopened in a clean area with an even temperature, preferably 23 to 86°F (-5 to +30°C) and relative humidity below 80%. The storage period (month and year) for filters is clearly marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eDISPOSAL:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eAfter use, remove from the respirator and treat the filter as special refuse and dispose of as solid waste in accordance with current waste treatment regulations based on the substance(s) filtered (gasses or particles). Please consult the appropriate local authority and\/or regulations for disposal advice and locations.\u003c\/span\u003e\u003c\/p\u003e","brand":"MIRA Safety","offers":[{"title":"Default Title","offer_id":44516676632752,"sku":"MIRA-PCAN","price":119.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/7725\/4832\/files\/mira-safety-p-can-police-and-corrections-gas-mask-filter-tactical-source-llc.jpg?v=1750241219"},{"product_id":"mira-safety-particlemax-p3-virus-filter-6-pack","title":"Mira Safety ParticleMax P3 Virus Filter 6 Pack","description":" \u003cp\u003e\u003cspan\u003eCombining cutting-edge ultra-low particulate air (ULPA) filtration with 40 mm standard NATO threading, these P3 certified biofilters work with your existing NBC\/CBRN gas mask to provide unparalleled, long-lasting protection from airborne viral and bacterial threats. These filters are vastly superior to common half-face masks in practically every scenario.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePlease Note:\u003c\/strong\u003e This bundle comes with 6 filters in total. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eKey Features of Mira Safety ParticleMax P3 Virus Filter\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e40 mm x 1\/7” NATO filter standard (EN 148-1:1999) threading\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eP3-certified protection (according to EN 143:2000 standards) filters out 99.9999+% of biothreats (not suitable for other CBRN threats)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLightweight (100g) construction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUtilizes some of the highest quality ULPA filter construction that works on particles as small as 0.2 microns\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePrevents aerosol and airborne transmission of viral and bacterial threats\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e20-year shelf life for easy long-term storage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHydrophobic filter paper is ideal for decontamination showers\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eMaximum Protection from Pandemic \u0026amp; Biological Threats\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eModern gas masks provide unparalleled protection from a wide variety of chemical, biological, radiological and nuclear threats. And now, with the new MIRA Safety ParticleMax P3 Filter, the same high-quality mask can protect you from bacterial and viral threats—including widespread pandemics like Ebola, coronavirus (including COVID-19) and H1N1.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis effectively turns your ultra-secure CBRN gas mask into a full-face respirator with the highest level of protection from airborne threats. Unlike common surgical masks and half-face respirators, you’ll get a perfect seal and full-face protection for everything including the soft tissue around your eyes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEngineered using the latest in ULPA filtration technology, the same kind you’ll find in “clean rooms” where semiconductors are manufactured. These P3 filters meet some of the highest standards in practically every metric. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThey’re made using special filtration media and grade 16 filter paper, resulting in a MERV rating of 20 (the highest attainable for air filtration quality). ULPA filters at this level are handcrafted using specially made fiberglass material, then pushed through a rigorous quality control process to ensure consistent quality across each and every filter. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThey’ve also been subjected to extreme testing to ensure they’ll filter out any and almost \u003c\/span\u003e\u003ci\u003e\u003cspan\u003eall \u003c\/span\u003e\u003c\/i\u003e\u003cspan\u003eenvironmental biothreats. The filter is even hydrophobic, so you can wear your mask in a decontamination shower without compromising your safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe end result?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #8b6a1b;\"\u003e\u003cb\u003eA filter and gas mask combo that’s practically \u003c\/b\u003e\u003cb\u003e\u003ci\u003eimpenetrable \u003c\/i\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #8b6a1b;\"\u003efor almost all of the world’s biothreats\u003c\/span\u003e.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTo infect you, viruses must enter your system through particulate or aerosol intrusion. Once you’ve got a perfect seal around your full face (possibly even reinforced with a full-body HAZ-SUIT), it is practically impossible for these threats to enter your body.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNOTE:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003eDue to their sophisticated and specialized construction, these filters will NOT provide protection from common CBRN threats and are primarily intended for protection from biological threats and airborne illnesses. We recommend keeping a variety of filters on hand to tackle whatever threat comes along. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis product comes in a pack of six (6) sealed filters with a shelf life of 20 years. They’re designed for easy long-term storage and handling, with a single package of six filters providing a solid amount of protection for one user (though we recommend stocking a full 2-week supply, if possible).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eCertification \u0026amp; Details:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e P3 R according to EN 143 Standard\u003c\/li\u003e\n\u003cli\u003eTH3 P R SL according to EN 12941\u003c\/li\u003e\n\u003cli\u003eTM3 P R SL according to EN 12942\u003c\/li\u003e\n\u003cli\u003e110 x 55 mm size\u003c\/li\u003e\n\u003cli\u003eSuitable for use with powered air purifying respirators (PAPR)\u003c\/li\u003e\n\u003cli\u003eCompatible with half-masks and full-face respirators\u003c\/li\u003e\n\u003cli\u003eCompatible with STANAG 4155, EN148-1, GOST threading\u003c\/li\u003e\n\u003cli\u003eP3 filtration removes 99.9999+% of airborne biothreats as small as 0.2 microns\u003c\/li\u003e\n\u003cli\u003eHydrophobic internal construction suitable for chemical showers\u003c\/li\u003e\n\u003cli\u003eIncinerable for safe disposal after use\u003c\/li\u003e\n\u003cli\u003eLess than .05% penetration at up to 95 l\/min. airflow\u003c\/li\u003e\n\u003cli\u003eProven in aerosol concentrations of up to 20 ± 5 mg\/m3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eStorage\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eOur P3 filters can be stored the same way you’d store other gas mask filters: in a cool, dry place away from exposure to hazardous substances. The filters should be stored in their original packaging at temperatures from −58 to 122°F (−50 to +50°С) protected from the effects of precipitation and groundwater. Maximum humidity during storage of the filters is 98%. Storage in places other than those specified can affect shelf life. Shelf life expiration is specified on each filter. The shelf life of each filter is 20 years.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eQuestions \u0026amp; Answers\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a 40mm NATO filter protect against COVID-19?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003e40mm NATO is a thread designation, not protection destination. For protection against COVID-19, you would look for a 40mm P3 filter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Viruses can only survive on surfaces for a period of a few days maximum. So if the only concern is only viruses like the coronavirus (and I don't have to worry at all about exposure to chemicals, etc.), why is it that gas mask filters cannot be reused after a few days, when any viruses that were on\/in it will no longer be a danger?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eFor safety reasons, we cannot recommend reusing any filter. This would go against all safety standards set out by regulatory agencies all over the world.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Will this filter work against deterrents used by LE such as tear gas or pepper spray. If not all, which ones are not covered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eNo, it will not, as this is just a particle filter. We would suggest the DOTpro 320 or NBC-77 SOF for riot control agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: I am using cerakote to coat and spray on multiple objects, will this be suitable to keep me safe? I would like to use my respirator that will take 40mm NATO instead of buying an additional mask for this task.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eAs cerakote is a solid particle traveling in a liquid aerosol, yes, this filter would work to keep you safe.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: I just bought the cm-6m. If I took the mask off in a controlled environment and left the filters in the mask after I had used it would they be okay? N95 masks are reusable until they are not structurally sound.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eThat depends on if the filters were used with live agents. If they were, they are considered toxic waste and must be disposed of for safety. N95 masks are only reusable so long as they are used with simple particulates (not viral, biological, CBRN, etc).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: I have some expired CNBC filters. I know the carbon aspect of the filter is what expires... Will that filter still remove COVID-19? They are still in original airtight packaging (40mm NATO type). Looking forward to the arrival of the order I put in with you all. I know you are severely backlogged. Your services are certainly appreciated!\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eWe cannot say for sure, as even particle filters have glue in them which can begin to flake over time, leading to gaps in the particle filter. For the sake of safety, we only recommend using in-date filters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many microns do these filters go down to?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eThe ParticleMax P3 will filter down to 0.2 microns and made from U16 ULPA filter paper. Viruses are smaller (0.004 to 0.1 microns), but the goal with virus filtration is to capture the particles that would host the virus. Aerosols particles are limited to 10 microns in size as coarse particles (over 10 μm) are liable to sedimentation and rapidly settle.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Will these fit Israeli gas masks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eYes they will.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What exactly does \"disposable, one-time use product\" mean? If in home quarantined and Convid-19 was the concern, would I have to discard after each 1-2 hour trip out to get gas and supplies? Or is there a procedure I could follow to leave attached and reuse? A direct answer or reference to procedure is appreciated. Thanks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eFor safety, yes, you would have to discard after each use. You cannot decontaminate the inside of a filter, so after one use, it becomes toxic waste. When you come back home from a supply run, you would have to fully decontaminate and learn proper doffing procedure (the industry term for removal of personal protective equipment). As part of decontamination, you would dispose of the filter in accordance with local laws.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it NIOSH approved?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eNo, it is not. However, this filter is compliant under European standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it necessary to use more than one filter for ample protection? What is the difference between using one filter or two filters at a time? Why do the CM-6M gas masks come with 2 filter ports? I am generally unclear as to whether or not any of the individual filters you sell online work independently or if I am required to purchase two of each for adequate filtration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eThe CM-6M and CM-7M masks could be used with one or two filters simultaneously. The benefit of using two at the same time is lower breathing resistance and more extended periods between swapping filters, but that comes at the expense of making the system more cumbersome. For that reason, we suggest using one filter at a time for most applications. Also, for tactical applications (using rifles), you have the option of attaching the filter on the left or right side, for left and right-handed shooters. This allows you to get closer to the stock of your firearm, as there is no filter in the way.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How long can you store masks and an assortment of filters in a vehicle without worrying about the degrading of MIRA products? I live in 4 seasons area.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eStoring MIRA products in a car is not recommended considering the fluctuation of temperature and humidity. If you commute with MIRA Safety products, we would suggest to bring them into your workplace during the day to avoid these fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Will these filters work for CA,OC,CS,CR PS \u0026amp; CN?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eThis filter is only intended to work with particulates, not riot control agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSince I don't have a decontamination shower how could I clean and remove my mask without getting contaminated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eRemoving personal protective equipment is called \"doffing\". To properly decontaminate would require special training. Users of our products are responsible for acquiring all necessary training. There are many resources available online, but we suggest taking an in-person class to maximize safety and proficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are these filters compatible with MIRA Safety CM-6M Tactical Gas Mask?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eYes, they are compatible with all MIRA Safety gas masks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How long can this be used before it needs to be replaced? Does one filter last a day or weeks etc? How do you know when to swap it? Thanks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eFilter use time depends on atmospheric conditions, the concentration of particles, along with your breathing rate. You will know to swap the filter when it becomes harder to breathe. If this filter is used with viral particles, it can only be used once. If it is used with standard particles, it can be used and reused for an extended period of time (that period would be determined by the factors outlined).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Once the filter is opened, how long will it last?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003eThis filter does not contain activated carbon, so as long as you keep it in ideal storage conditions, it will last 20 years even if it's opened.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Approximately how many hours\/days will one filter last one person with continuous use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\n\u003cp\u003e\u003cspan\u003eThat depends on a few factors, including atmospheric conditions, breathing rate, and particle concentration. For viral particles, this filter will last for as long as you can wear the mask. Keep in mind, filters are disposable one-time use products, and it's not safe to re-use a filter once it's come into contact with live agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MIRA Safety","offers":[{"title":"Default Title","offer_id":44516772544688,"sku":"MIRA-PARTICLEMAX","price":474.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/7725\/4832\/files\/mira-safety-particlemax-p3-virus-filter-6-pack-tactical-source-llc.jpg?v=1750243193"},{"product_id":"mira-safety-cbrn-gas-mask-filter-nbc77-40mm-thread-canister","title":"Mira Safety CBRN Gas Mask Filter NBC77 SOF 40mm Thread Canister","description":" \u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eFILTRATION TECHNOLOGY YOU CAN DEPEND ON\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe NBC-77 SOF filter canister, in combination with a full-face mask, mouthpiece assembly, or PAPR, reliably protects air passages against a wide range of harmful and highly toxic substances including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eall known CBRN agents.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe filters are produced with standard round threads according to STANAG 4155 (EN 148- 1)- Rd 40x1\/7\". The filter components are made of hard plastic. This results in a very robust product that is extremely durable against shock and impact damage in operational use.\u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #8b6a1b;\"\u003eFeatures of Mira Safety CBRN Gas Mask Filter NBC77 40mm Thread Canister\u003c\/span\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with standard 40mm NATO threaded respirators, which are widely available.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e20-year shelf life - save money long-term by not having to replace your filters every 5 years\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUsed by military personnel, CBRN specialists, and special operations forces all over the world\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFilter all known CBRN agents, including radioactive iodine, rated for A2B2E2K2HgSXP3 D R.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCertified by European agencies and has the “CE” symbol. Compliant under EN 14387:2004 + A1:2008\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-lboi{border-color:inherit;text-align:left;vertical-align:middle}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" class=\"tg-lboi\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eTechnical Data\u003c\/span\u003e\u003c\/th\u003e\n\u003cth colspan=\"2\" class=\"tg-lboi\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBreathing Resistance in Pa\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eDiameter\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e110 mm\u003c\/td\u003e\n\u003ctd rowspan=\"4\" class=\"tg-lboi\"\u003e@ flow rate 30l\/min. EN 1) NBC-77 SOF 260 \u0026lt;140\u003c\/td\u003e\n\u003ctd rowspan=\"4\" class=\"tg-lboi\"\u003e@ flow rate 95l\/min. EN 1) NBC-77 SOF 980 \u0026lt;600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003e\n\u003cp\u003eHeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e335 g ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eStorage time\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e20 years (factory sealed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-lboi{border-color:inherit;text-align:left;vertical-align:middle}\n.tg .tg-g7sd{border-color:inherit;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-0a7q{border-color:#000000;text-align:left;vertical-align:middle}\n.tg .tg-73oq{border-color:#000000;text-align:left;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-g7sd\" colspan=\"2\"\u003eType and Class Particle filter efficiency @ flow rate 95l\/m\u003c\/th\u003e\n\u003cth class=\"tg-g7sd\" colspan=\"3\"\u003eParticle filter efficiency @ flow rate 95L\/M\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eA2 - organic gases and vapors\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003eSX - CG, CK, PS\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\" rowspan=\"5\"\u003eSodium Chloride NaCl (S) Paraffin oil (L)\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\" rowspan=\"5\"\u003eEN 99.95 99.95\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\" rowspan=\"5\"\u003eNBC-77 SOF \u0026gt;99.999 \u0026gt;99.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eB2 - inorganic gases and vapors\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003eP3 - particles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eE2 - acid gases and vapors\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003eD- dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eK2 - ammonia and amines\u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003eR- reusable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-73oq\"\u003eHg - mercury vapors\u003c\/td\u003e\n\u003ctd class=\"tg-73oq\"\u003eREACTOR - radioactive iodine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cspan style=\"color: #8b6a1b;\"\u003e\u003c\/span\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eApplication\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe filter canister in connection with a suitable respirator or PAPR provides protection against solid and liquid particles, pepper spray (OC), smoke-producing substances, radioactive particles, bacteria and rickettsia, fungi, toxins, viruses, riot control agents (lachrymators, sternutators, vomiting agents), blister agents (vesicants), choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides, and TIC, such as bromoacetone, CS, CR, CN, CNC, CNS, CA substances, organic compounds of arsenic - diphenyldichlorarsine - CLARK I (DA), diphenylcyanoarsine - CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulphur mustard gas (HD), T-mustard gas, Q-mustard gas, nitrogen mustard gases (HN1, HN2, HN3), lewisite (L), mixed mustard gas (H-L), phosgene oxime (CX), phosgene (CG), diphosgene(DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G-agents: sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), V-agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: fumes of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65° C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapors, radioactive iodine, organic compounds of iodine (Iodomethane, 129, 131), radioactive particles, etc.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-u8bn{background-color:#efefef;border-color:#000000;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-1tol{border-color:#000000;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-0a7q{border-color:#000000;text-align:left;vertical-align:middle}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\" colspan=\"3\" class=\"tg-1tol\"\u003eTesting Gas\u003c\/th\u003e\n\u003cth colspan=\"3\" class=\"tg-1tol\"\u003eConcentration of Testing Gas\u003c\/th\u003e\n\u003cth rowspan=\"2\" class=\"tg-1tol\"\u003eBreakthrough Time in Minutes EN\u003c\/th\u003e\n\u003cth rowspan=\"2\" class=\"tg-1tol\"\u003eNBC-77 SOF\u003c\/th\u003e\n\u003cth rowspan=\"2\" class=\"tg-1tol\"\u003eDAC in Grams NBC-77 SOF\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-u8bn\"\u003ePPM\u003c\/th\u003e\n\u003cth colspan=\"2\" class=\"tg-u8bn\"\u003eMG\/I\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003eA2\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eCyclohexane\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eC₆H₁₂\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e17.5\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e35\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e39\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e20.475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003eB2\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eChlorine\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eCl₂\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e15\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e20\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e45\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e20.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eHydrogen Sulphide\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eH₂S\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e7.1\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e40\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u0026gt;80\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u0026gt;17.400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eHydrogen Cyanide\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eHCN\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e5.6\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e25\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e50\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e8.400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003eE2\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eSulphur Dioxide\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eSO₂\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e13.3\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e20\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e25\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e9.975\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003eK2\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eAmmonia\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eNH₃\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e3.5\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e40\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e50\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003eHg\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eMercury\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eHg\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e-----\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e13 mg\/m³\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e100 hours\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u0026gt;170 hours\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u0026gt;3.900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003eSX\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eCyanogen chloride\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eCICN\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e2500\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e6.28\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e20\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e25\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e4.710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eChloropicrin\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eCCI₃NO₃\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e33.55\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e20\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e44\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e44.286\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003ePhosgene\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eCOCl₃\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e5000\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e20.24\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e20\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u0026gt;77\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u0026gt;47.058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0a7q\"\u003eREACTOR\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eMethyloidide₁₃₁\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003eCH₃I\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e-\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"tg-0a7q\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e2 hours\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e\u0026gt;2 hours\u003c\/td\u003e\n\u003ctd class=\"tg-0a7q\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eLifetime\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eBreakthrough time of a filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l\/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.\u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #8b6a1b;\"\u003eStorage and Maintenance\u003c\/span\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe filters are sealed in plastic bags by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50°C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eDisposal\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAfter use, the filters are special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2262\/5147\/files\/NBC-77_SOF_Filter_Brochure-compressed.pdf\" title=\"Mira Safety NBC-77 SOF CBRN Filter Canister\" target=\"_blank\"\u003eClick here to download the Brochure\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #8b6a1b;\"\u003eQuestions and Answers\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: I am aware that a P3 filter is required to block the coronavirus. Which one of your filters is P3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: \u003c\/strong\u003eMIRA Safety filters (NBC-77 SOF, VK-450, DOTpro 320) are classified as \"combined filters\" and contain a P3 filter along with activated carbon. For those that don't know what P3 means, it is a rating for a particle filter that blocks 99.9999%+ of particulates. As viruses travel in liquid aerosols and particulates, this filter (when coupled with a full face respirator) would prevent the coronavirus from entering your breathing passages and eyes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How long does a filter last once it's opened?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Filter use time depends on a few factors, including atmospheric conditions, contaminant type, concentration, along with your breathing rate. As a general rule of thumb, we would suggest having two filters per person per day for emergency evacuation purposes. If you'd like specific data on use time, you can look at the brochure that goes into breakthrough times along with the application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Would this be compatible with the North by Honeywell Small Elastomer Full Face 5400 Series Dual Cartridge Facepiece?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA:\u003c\/strong\u003e For viral filtration, you would need a P3 particle filter (all of our filters have a P3 built-in). As all of our filters are threaded for 40mm NATO, they will all fit the MSA Millenim mask.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e \u003cstrong data-mce-fragment=\"1\"\u003eWhat level filter will protect me from the Coronavirus and will this filter fit the MSA millennium gas mask?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e \u003cspan data-mce-fragment=\"1\"\u003eFor viral filtration, you would need a P3 particle filter (all of our filters have a P3 built-in). As all of our filters are threaded for 40mm NATO, they will all fit the MSA Millenim mask.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e \u003cstrong data-mce-fragment=\"1\"\u003eDoes this filter fit the Polish MC-1 gas mask?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e \u003cspan data-mce-fragment=\"1\"\u003eYes, it does, so long as it's in 40mm NATO configuration. As this is an old mask it might be threaded in 40mm Soviet GOST. Make sure to double-check before making a purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eQ: \u003cstrong data-mce-fragment=\"1\"\u003eWill these filters work with an Avon C50 to provide proper CBRN threat protection?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003eYes, they will, as both are threaded for 40mm NATO.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eQ: Will these filters fit on Soviet GP5 gas masks?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No, they will not, as they are threaded for 40mm NATO, and the GP5 is threaded for old-style 40mm GOST.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eQ: Will these filters fit Israeli gas masks?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, they will, as both are 40mm NATO threaded.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e \u003cstrong data-mce-fragment=\"1\"\u003eHow to properly clean the mask? How to properly dispose of a used filter? For both, in a case where you may fear you were in a contaminated area.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA: \u003c\/strong\u003e\u003c\/span\u003eThere are many cleaning products on the market for gas masks, and each is created for different purposes. As decontamination is a field of study on its own, we would suggest doing independent research and training before purchasing cleaning products. For viral threats, we have heard that Allegro 5003-U is a good product from industry experts. We do not sell it on our website, but you can find it in shops across the web. Filter disposal would depend on local laws for toxic waste disposal. Please check with local authorities as laws differ from county to county, state to state, and country to country.\u003c\/p\u003e\n\u003cp\u003eQ: \u003cstrong data-mce-fragment=\"1\"\u003eWhy are these masks not NIOSH approved? Is it primarily because of geographical usage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e \u003cspan data-mce-fragment=\"1\"\u003ePrecisely. Traditionally, these masks were used by professionals in the EU, the middle east, along with eastern-European counties. \u003cspan data-mce-fragment=\"1\" class=\"style-scope yt-formatted-string\" dir=\"auto\"\u003eBoth the CM-6M and CM-7M are EN 136 CL 3 (special purpose) certified. If you look through and compare NIOSH testing to EN, you will see that EN standards are just as stringent as their NIOSH counterparts. \u003c\/span\u003e \u003cspan data-mce-fragment=\"1\" class=\"style-scope yt-formatted-string\" dir=\"auto\"\u003eNIOSH does not determine quality by any means, just an extra piece of certification as mandated by OSHA for private sector professional use. Keep in mind, government-owned agencies are not subject to OSHA and can use non-NIOSH masks\/filters. This includes police, fire brigades, first responders, etc. All of which are our customers in the US.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" class=\"style-scope yt-formatted-string\" dir=\"auto\"\u003e\u003cstrong\u003eQ: How long will a NBC-77 SOF filter protect in non-contaminated air against viruses?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" class=\"style-scope yt-formatted-string\" dir=\"auto\"\u003e\u003cstrong\u003eA: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\" dir=\"auto\"\u003eAs viruses travel in particles and liquid aerosols, this filter will protect you for as long as you can wear the mask (several days). Keep in mind; if you are in a contaminated environment, you would need to decontaminate properly before removing your protective gear, and then dispose of the filter as there is no way to regenerate it. Once the filter is used in a contaminated environment, it is considered toxic waste.\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\" dir=\"auto\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MIRA Safety","offers":[{"title":"Black","offer_id":44516776181936,"sku":"MIRA-NBC77SOF-BLACK","price":139.5,"currency_code":"USD","in_stock":false},{"title":"Ranger Green","offer_id":44516776214704,"sku":"MIRA-NBC77SOF-RANGER","price":139.5,"currency_code":"USD","in_stock":false},{"title":"Sandstone","offer_id":44516776247472,"sku":"MIRA-NBC77SOF-SANDSTONE","price":139.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/7725\/4832\/files\/mira-safety-cbrn-gas-mask-filter-nbc77-sof-40mm-thread-canister-tactical-source-llc.jpg?v=1750243236"},{"product_id":"msa-advantage-1000-cba-rca-cannister-box-of-6","title":"MSA Advantage 1000 CBA-RCA Canister Box of 6","description":"\u003cp\u003eAdvantage 1000 Gas Mask Cartridge, Bayonet Mount Canister, Chemical \/Biological\/Riot Control Agent. Effective against biological and chemical warfare agents including Tabun, Sarin, Soman, VX, Mustard, Lewisite and are NIOSH approved for protection from Chloroacetophenone (CN), Chlorobenzylidene (CS), P100 particulates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMSA Advantage 1000 CBA-RCA \u003cspan\u003eCanister\u003c\/span\u003e Features and Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNIOSH approved for CBA\/RCA agents\u003c\/li\u003e\n\u003cli\u003eFull protection against all known biological and chemical agents\u003c\/li\u003e\n\u003cli\u003eThird party tested against chemical warfare gases\u003c\/li\u003e\n\u003cli\u003eExcellent protection against Sarin (and its surrogate DMMP)\u003c\/li\u003e\n\u003cli\u003eDesigned for protection against chem-warfare gases\u003c\/li\u003e\n\u003cli\u003eUsed by the majority of federal and local agencies\u003c\/li\u003e\n\u003cli\u003eParticulate filter is over 99.99% efficient against all particulates and is appropriate for protection against biological aerosols.\u003c\/li\u003e\n\u003cli\u003eSlim profile perfect for face shields and helmets\u003c\/li\u003e\n\u003cli\u003ePermissible Canister for P100\/CS\/CN ++\u003c\/li\u003e\n\u003cli\u003eSix (6) \u003cspan\u003eCanister\u003c\/span\u003e per box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"MSA","offers":[{"title":"Default Title","offer_id":44517252268208,"sku":"817590","price":499.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/7725\/4832\/files\/msa-advantage-1000-cba-rca-canister-box-of-6-tactical-source-llc.jpg?v=1750250126"},{"product_id":"msa-millennium-cbrn-cannister-10046570","title":"MSA Millennium CBRN Cannister Box of 6","description":"\u003cp\u003eMillennium Gas Mask Cannister, 40mm Canister thread, Chemical \/Biological\/Riot Control Agent and Nuclear. Effective against biological and chemical warfare agents including Tabun, Sarin, Soman, VX, Mustard, Lewisite and are NIOSH approved for protection from Chloroacetophenone (CN), Chlorobenzylidene (CS), P100 particulates. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMSA Millennium Cannister Features and Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e40mm NATO threaded low profile design preferred by law enforcement\u003c\/li\u003e\n\u003cli\u003eFull protection against all known biological and chemical agents\u003c\/li\u003e\n\u003cli\u003eThird party tested against chemical warfare gases\u003c\/li\u003e\n\u003cli\u003eParticulate filter is over 99.99% efficient against all particulates and is appropriate for protection against all biological aerosols\u003c\/li\u003e\n\u003cli\u003eExceptionally high particle-filtration capacity and low breathing-resistance\u003c\/li\u003e\n\u003cli\u003eManufactured in a sealed foil bag\u003c\/li\u003e\n\u003cli\u003eStandard 40mm NATO threaded\u003c\/li\u003e\n\u003cli\u003eSix (6) Cannister\/Cartridge per box\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MSA","offers":[{"title":"Default Title","offer_id":44517252726960,"sku":"MSA-10046570","price":1195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/7725\/4832\/files\/msa-millennium-cbrn-cannister-box-of-6-tactical-source-llc.jpg?v=1750250131"},{"product_id":"vts-ventura-tactical-systems-cbrn-canister","title":"VTS Ventura Tactical Systems CBRN Gas Filter Canister","description":"\u003cp\u003e\u003cstrong\u003ePREORDER: \u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eNote: Gas Filters are Made in China.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas mask Cartridge quality: 1\/2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas mask Total visual field: \u0026gt;81%\u003c\/li\u003e\n\u003cli\u003eGas mask inhalation resistance: ≤25pa(30Lmin)\u003c\/li\u003e\n\u003cli\u003eGas mask oil mist transmittance: ≤0.0005%\u003c\/li\u003e\n\u003cli\u003eGas mask certificate: CE EN136, ISO\u003c\/li\u003e\n\u003cli\u003eGood seal\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpeech diaphragm\u003c\/li\u003e\n\u003cli\u003eRD40 connection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ventura Tactical Systems","offers":[{"title":"Default Title","offer_id":44519355875504,"sku":"VTS-GMC-01","price":89.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/7725\/4832\/files\/vts-ventura-tactical-systems-cbrn-gas-filter-canister-tactical-source-llc.jpg?v=1750265269"}],"url":"https:\/\/tacticalsource.com\/collections\/gas-mask-filters.oembed","provider":"Tactical Source LLC","version":"1.0","type":"link"}